| Sign In | Join Free | My bushorchimp.com |
|
Insulation Material : Silicone
rated voltage : 300-600V
Model NO. : Silicone Cable
rated temperature : -60± 200℃
Copper : Tinned Copper
Customization : Available
specifications : 0.1-450mm²
Application : Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car, Construction, Power Plant, Underground, Industrial
conductor material : copper/Tinned Copper
insulating materials : customize:PVC、PE 、XLPE、EPR、SIR
Voltage : Low and Medium Voltage Cable
Return&refunds : You can apply for a refund up to 30 days after receipt of the products.
Exterior material : customize:PVC、PE、LSFOH、silicone rubber
MOQ : 1000 m
Price : Negotiable
Packaging Details : According to requirement
Delivery Time : 7-15 days
Payment Terms : Advance 30% deposit and ship after receiving 70% final payment
Supply Ability : 50000m/day
Place of Origin : Guangdong, China
Brand Name : Linke
Core : Multiple
Conductor Type : Twisted wire
Certification : 3C,UL,TPU,UL758,ROHS,REACH,CE,ISO9001-2015,ISO13485,IATF16949
colour : customize
Material Shape : Round Wire
Wire Core Material : Tinned Wire
type : insulated
Shipping Cost : about shipping cost and estimated delivery time.
| AWG Size | Conductor Structure | Conductor OD (mm) | Insulation Thickness (mm) | Cable OD (mm) | Resistance (Ω/KM Max) |
|---|---|---|---|---|---|
| 16 | 7/0.49 | 1.55 | 1.28 | 4.5 | 14.6 |
| 15 | 33/0.254 | 1.75 | 1.28 | 4.7 | 11.3 |
| 14 | 41/0.254 | 1.95 | 1.28 | 4.9 | 8.96 |
| 13 | 52/0.254 | 2.15 | 1.28 | 5.1 | 7.1 |
| 12 | 65/0.254 | 2.5 | 1.28 | 5.5 | 5.64 |
| 11 | 83/0.254 | 2.74 | 1.28 | 5.7 | 4.48 |
| 10 | 35/0.45 | 3.2 | 1.28 | 6.2 | 3.55 |
| 9 | 53/0.40 | 3.98 | 1.28 | 7.0 | 2.81 |
| 8 | 70/0.40 | 4.4 | 1.28 | 7.4 | 2.3 |
| 7 | 84/0.40 | 4.6 | 1.28 | 7.7 | 1.79 |
| 6 | 105/0.40 | 5.3 | 1.28 | 8.4 | 1.42 |
| 5 | 133/0.40 | 6.0 | 1.28 | 9.1 | 1.12 |
| 4 | 168/0.40 | 6.8 | 1.28 | 10.0 | 0.89 |
| 3 | 210/0.40 | 7.6 | 1.28 | 10.8 | 0.707 |
| 2 | 266/0.40 | 8.5 | 1.28 | 11.7 | 0.56 |
| 1 | 217/0.50 | 9.6 | 1.28 | 13.3 | 0.449 |
| Brand | LINKE | Cross Section (mm²) | 0.01-500mm² |
| Wire Gauge (AWG) | [e.g., 24AWG, 28AWG] | Conductor | Tinned Copper /bare copper, based on client's requirements |
| Insulation material | PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other | Jacket Material | [PVC/PU/Rubber/Braid/etc.] |
| Certifications | RoHS/REACH/UL/CE/IP68/etc | Custom Length | [e.g., 1m, 3ft, 5m ±5% tolerance] |
| Cable Type | [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] | Shielding | [Shielded/Unshielded/Braid Shield] |
| Impedance | [e.g., 75Ω (for coaxial cables)] | Printing/Logo | [Text/Label/Logo, max. 20 characters] |
| Bend Radius | [e.g., ≥5× cable diameter] | Current Rating | [e.g., 5A] |
| Voltage Rating | [e.g., 30V AC/DC] | Connector Material | [Gold-plated/Nickel-plated/Brass/etc.] |
| Connectors | [e.g., USB Type-C, 3.5mm Jack, RJ45] | Jacket | XLPE or PE or PVC RUBBER |
| Delivery Time | 7-14 days after confirming the order | Colors | [Black/White/Red/Custom Pantone/etc.] |
| temperature | Minus-70℃to 350℃(-70℃ ~ 350℃) | Package | Roll/box/plate/Custom |
| Supporting Services | multicolumn {3}{l}{custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated) |
| No. | Test Item | Test Condition | Test Requirement | Test Data | Result |
| 1 | Structure Inspection | 1. Comply with wire size table2. Minimum thickness ≥ 80% of average thickness | Comply with wire size table | Refer to test record | Pass |
| 2 | Thermal Shock | Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample | No cracks on the sample surface | No cracks | Pass |
| 3 | Heat Deformation | 1. Measure sample thickness (mark measurement position)2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour3. Place sample under pressure column of test fixture for 1 hour4. Re-measure sample thickness at the same position | 1. Sample shall not be cracked by pressure column or expose conductor2. Thickness reduction ≤ 50% | Refer to test record | Pass |
| 4 | FT2 | Apply a standard flame at a height of 125mm once | 1. Flame shall not propagate along its length2. Flame shall not spread to nearby flammable materials | Refer to test record | Pass |
| 5 | Aging | 1. Take five sections of 200mm-long sheath2. Place specimens in aging oven at 158℃ for 168 hours3. After taking out specimens, place at room temperature 23±5℃ for 16 hours, then test elongation at break and tensile strength | 1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging | Refer to test record | Pass |
| 6 | Cold Bend | Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box | No cracks on the sample surface | No cracks | Pass |
| 7 | Conductor Resistance | Measure resistance of one-meter core conductor with DC resistance meter | At 20℃, resistance of 8AWG ≤ 2.23Ω/km | Refer to test record | Pass |
|
|
Heat Resistant Silicone Cable with Multiple Core 0.5mm Flexible Silicone Wire for High Temperature Applications Images |